Jiangsu Chaori Purification Technology Co., Ltd.

High concentration of acid and alkali exhaust gastreatment equlpment

Location:Home > High concentration of acid and alkali exhaust gastreatment equlpment

  • DGS-B Industrial Wet Scrubbers for Acid Gases
  • DGS-B Industrial Wet Scrubbers for Acid Gases
  • DGS-B Industrial Wet Scrubbers for Acid Gases
1/3

上一张

下一张

DGS-B Industrial Wet Scrubbers for Acid Gases

With a DGS-B industrial wet scrubber, you can handle high-concentration acid, alkali, and mixed water-soluble gases in your facility. Each system is custom-engineered for your gas composition, airflow, and plant layout, ensuring reliable performance, corrosion resistance, and long-term efficiency. Our solutions are built to meet your environmental requirements and international emission standards.

Technical Strengths

Our DGS-B systems provide you with high-performance, reliable solutions for demanding industrial environments:

Corrosion-Resistant Materials: Built with FRP for harsh acidic and alkaline conditions.

High Removal Efficiency: Optimized spray system, structured packing, and demisters maximize gas-liquid contact.

Energy-Efficient and Low Noise: Operates quietly while consuming minimal energy.

Process-Specific Design: Tailored to your gas composition, concentration, and facility layout.

Gas Handling Capability: Efficiently treats HF, HCl, H2SO4, H2S, NH3, NaOH, HCHO, CrO3, HCN, and other water-soluble acidic, alkaline, or mixed gases.

Reliable and Stable Operation: Maintains performance under continuous, high-concentration exhaust conditions.

Designed in accordance with ASME RTP-1 standard and manufactured in accordance with ASTM 3299D standard.

Industry Applications

Our DGS-B industrial wet scrubbers are ideal for handling corrosive and high-concentration gases in your facility. 

They are widely used in:
Chemical and petrochemical plants: controlling acid and alkali emissions from production lines.
Electroplating and metal surface treatment: managing plating and pickling fumes efficiently.
Solar and semiconductor manufacturing: safely removing acid mist from wafer cleaning processes.
Boilers and industrial furnaces: treating corrosive gases in energy generation systems.
Electronics and instrumentation manufacturing: ensuring clean exhaust in sensitive production areas.

Don’t see your industry listed? Contact us for a fully customized solution tailored to your facility and process.

Exhaust gas treatment performance table

ingredient concentrationmg/m3 Purification efficiency% Neutralizing and absorbing solution
HNO3 ≤200 ≥95 2~7%NaOH liquor and 3-4%Na2S liquor
NOX ≤2000 ≥95 7%NaOH liquor and 3-4%Na2S liquor
HF ≤400 ≥95 2~7%NaOH liquor
HCl ≤400 ≥98 2~7%NaOH liquor
H2SO4 ≤400 ≥95 2~7%NaOH liquor
NH3 ≤4000 ≥99 water solution or 2~7%NaOH liquor

Acid mist purification tower

Installation size and foundation

Acid mist purification tower

About Chaori

With over 20 years of experience in designing and delivering industrial exhaust solutions, Chaori is a trusted partner for your facilitys gas treatment needs.

Our capabilities include:

Engineering & Manufacturing: 20+ years of experience and a team of skilled engineers handling every step from design to installation.

Facilities: 30,000 m² production area with multiple workshops and assembly lines to ensure timely delivery.

Quality & Certification: Strictly following ISO 9001:2015 quality management standards.

Global Support: Systems designed to meet international safety and emission standards, with lifetime consultation available.

Contact us today to discuss a custom solution for your industrial gas challenges.

Process principle of industrial waste gas wet scrubbers

Under the action of the fan, the exhaust gas reaches the bottom packing bed, enters the pressure balancing room formed by the internal and external jacket at a low speed, and is transported by circulating pump and washed countercurrent. The exhaust gas is evenly distributed around the PP Terary barbed garland +PP multi-sided hollow ball alternating packing layer, each showing point contact, arranging "Z or W" irregular route walking, without bias phenomenon. Then with the spiral high flow, not blocking the nozzle, so that the gas-liquid two-phase mixing rate of more than 97%, so that the exhaust gas to get the gas-liquid two-phase full contact reaction, and then through the deliquid defogging, to meet the national GB16297-1996 "comprehensive emission standards for air pollutants" in the secondary emission requirements, and finally through the exhaust pipe into the atmosphere.

Acid mist purification tower

Packing & Delivery

package-930px.jpg

I want to customize:DGS-B Industrial Wet Scrubbers for Acid Gases

  • *Contact person:
  • Company name:
  • *Email:
  • Purchase intention:
  • *Verification code: Verification Code

Related ProductsRelated Products

CR-BF High-Concentration FRP Acid Mist Scrubber

CR-BF High-Concentration FRP Acid Mist Scrubber

With a CR-BF FRP Acid Mist Scrubber, you can efficiently treat high-concentration NOx, HCl, HNO3, HF...

Learn More
DGS-B Industrial Wet Scrubbers for Acid Gases

DGS-B Industrial Wet Scrubbers for Acid Gases

With a DGS-B industrial wet scrubber, you can handle high-concentration acid, alkali, and mixed wate...

Learn More
Leave A Message Request A Free Quote
For more product details and new products, please leave a message.We'll reply quickly!